Battery a Wɔde Di Dwuma Ho Nhyehyɛe
Battery Management System (BMS) yɛ afiri a wɔde di dwuma de hwɛ batere so yiye. Wɔ anyinam ahoɔden kar ho no, BMS hardware ne software a wɔayɛ no yie{1}}bɛtumi ama karka akɔ soro yie, atrɛw battery pack nkwa nna mu, atew adwumayɛ ho ka so, na ahwɛ sɛ ahoɔden battery pack no ahobanbɔ ne ahotosoɔ. Batere a wɔde di dwuma wɔ anyinam ahoɔden so no abɛyɛ ade titiriw a ɛho nhia wɔ kar ahorow a anyinam ahoɔden wom mu. Saa ti yi bɛtwe adwene asi nneɛma a wɔahyehyɛ, dwumadie, ne adwumayɛ nnyinasosɛm a ɛwɔ ahoɔden batere sohwɛ nhyehyɛeɛ no mu.
Nhyehyɛe a Wɔde Yɛ Nneɛma
Battery management system (BMS) hardware a wɔtaa yɛ no titire no bi ne Battery Management Unit (BMU), Cell Management Unit (CMU), sensors, wiring harnesses, ne nea ɛkeka ho Wɔ nhyehyɛe akɛse-scale power battery systems mu no, BMS architecture a wɔpaw no ho hia yiye, ɛkyerɛ tẽẽ nkitahodi akwan a ɛda hardware units ne software nhyehyɛe kwan no ntam, na ɛka system no ka, ahotoso, sɛnea ɛyɛ mmerɛw sɛ wɔde bɛhyɛ mu na wɔasiesie, ne susudua a ɛyɛ pɛpɛɛpɛ. Wogyina topology a ɛda controllers ntam wɔ BMS no so no, wobetumi akyekyɛ BMS ahorow no mu kɛse ayɛ no ahorow abien: wɔaka abom ne nea wɔakyekyɛ.
1. BM a wɔaka abom

2. BMS a wɔakyekyɛ
Nea ɛnte sɛ topologies a wɔaka abom no, architectures a wɔakyekyɛ mu no kyekyɛ BMS dwumadie no mu yɛ no mainboard BMU ne nkoa CMU ahodoɔ pii. Modular nhyehyɛe no ma module nhyiam yɛ mmerɛw, ɛma sampling harness nhyehyɛe yɛ papa, na ɛtew voltage drop inconsistencies so ne uniform spacing. Nea enye wɔ ho ne ɛka a ɛkɔ soro ne nkitahodi ne nhyehyɛe a ɛyɛ den a wɔde di dwuma. Wogyina BMS nkitahodi akwan ahorow a wɔakyekyɛ so no, wobetumi akyekyɛ mu bio ayɛ no ahorow abiɛsa: nsoromma nkitahodi (hwɛ Mfonini 8-2), bɔs nkitahodi, ne daisy-nkɔnsɔnkɔnsɔn nkitahodi.
(1) Nsoromma NkitahodiWɔ nsoromma nkitahodi mu no, mainboard BMU no wɔ mfinimfini, na CMU module biara nam harness so na ɛka BMS mainboard no ho tẽẽ. Nsoromma nkitahodi ma point-to-point control yɛ mmerɛw, na CMU node biako huammɔdi nnya nhyehyɛe no so nkɛntɛnso kɛse. Nanso, bere a module dodow kɔ soro no, nkitahodi nhama a ɛyɛ den wɔ nsoromma nkitahodi mu no kɔ soro kɛse, na ɛma nsiesie yɛ den na ɛto scalability ano hye. Esiane anohyeto ahorow a ɛwɔ BMS mainboard ports no mu nti, wontumi mfa CMU modules nka ho wɔ ɔkwan a wɔpɛ so, na ɛma ɛyɛ nea ɛntaa nsi koraa wɔ application akɛse-scale mu.
(2) Bɔs NkitahodiBus-based system architecture ma modular design yɛ mmerɛw, sɛnea wɔakyerɛ wɔ Mfonini 8-3 mu no. Wɔtaa kyekyɛ BMS no mu yɛ no control units pii: BMU, CMU, ne Battery Join Box (BJB). BMU, CMU, ne BJB no nam CAN anaa bɔs ntam nkitahodi afoforo so na ɛka bom. BMU no yɛ algorithm dwumadie titire no ma battery management; CMU no yɛ cell voltage a wonya, equalization, ne ɔhyew susuw; BJB no yɛ ahoɔden a ɛkorɔn, mprempren, ne ɔhyew a wonya, contactor karka ne diagnostics, ne insulation detection ma battery pack no; isolation ma anyinam ahoɔden tew ne ho, na ɛmma backflow nhyew circuit board no na ɛto interference amplitude ano hye.
Bus-gyinasoɔ nhyehyɛɛ no ma nkitahodiɛ nkitahodiɛ a ɛyɛ mmerɛw ne scalability a ɛyɛ den, ɛma hardware architecture nhyehyɛɛ yɛ mmerɛ kɛseɛ, ɛma modularity, na ɛma system dwumadie ne portability tu mpɔn. Nea enye koraa ne sɛnea ɛho ka yɛ den kakra.

Daisy-chaining yɛ nkitahodi kwan foforo koraa a aba wɔ nnansa yi mfe mu. Interface no tumi dane full-duplex SPI signals a ɛkɔ 1Mb/s kɔ differential signals na ɛde fa twisted-pair cable ne transformer a ɛnyɛ den, a ne bo nyɛ den -fa so de mena. Sɛ nhwɛso no, wobetumi de Linear Technology AFE mfiri (LTC6811) abɔ mu ayɛ BMS. Transformer ketewa bi a ne bo nyɛ den-sesa data isolator no. Wɔ main control microprocessor fã no, adapter IC ketewa bi (LTC6820) ma controller titiriw interface no. Bere a unidirectional daisy-chain networking yɛ mmerɛw no, node biara huammɔdi betumi aka nhyehyɛe no nyinaa nkitahodi. Enti, wɔayɛ ring daisy-nkɔnsɔnkɔnsɔn a wɔatu mpɔn, sɛdeɛ wɔakyerɛ wɔ Mfonini 8-4 mu no, na wɔde adi dwuma wɔ BMS nneɛma a ɛwɔ kar akɛseɛ a wɔyɛ ahoɔden foforɔ te sɛ Tesla mu. Sɛ yɛde toto CAN bɔs nkitahodi ho a, daisy-chaining boɔ sua na ɛyɛ ketewa wɔ ne kɛseɛ mu, nanso ɛwɔ scalability a ɛnyɛ papa, nodes dodoɔ a ɛboro soɔ a anohyetoɔ wɔ mu, ne ɔhaw wɔ battery management nsɛm ho dwuma wɔ tebea a ɛyɛ den te sɛ ahoɔden akoraeɛ nhyehyɛeɛ akɛseɛ mu.

Dwumadie Mfitiaseɛ
Mpɛn pii no, dwumadie titire a ɛwɔ Battery Management System (BMS) mu no bi ne: data a wɔgye, battery tebea ho akontabuo, ahoɔden a wɔde di dwuma, ahobanbɔ ho nhyehyɛeɛ, ɔhyeɛ sohwɛ, pɛyɛ sohwɛ, nkitahodiɛ dwumadie, ne nnipa-mfiri ntam nkitahodi. Mfonini 8-5 kyerɛ dwumadie block diagram a ɛkyerɛ battery management system.

1. Data a Wonya
Data a wɔgye yɛ algorithms ne controls nyinaa fapem wɔ Battery Management System (BMS) mu. Enti, sampling rate, pɛpɛɛpɛyɛ, ne pre-filter su yɛ nsɛnkyerɛnne a ɛho hia a ɛka battery system adwumayɛ. Wɔnam tebea ne dwumadie so na ɛkyerɛ data a wɔbɛnya no dodoɔ. Sɛ nhwɛso no, sɛ wɔde backup power supply di dwuma a, data a wonya no dodow betumi ayɛ ketewaa bi te sɛ frame biako wɔ sikɔne 10 biara mu anaasɛ simma biara mpo; bere a wɔ nneɛma a ɛwɔ current a ɛsakra ntɛmntɛm (te sɛ kar) ho no, ɛsɛ sɛ wonya data anyɛ yiye koraa no pɛnkoro wɔ sekan 1 biara mu, a ahobammɔ-fata data bi hwehwɛ sɛ wɔde sampling frequencies a ɛba fam te sɛ 100ms anaa 10ms.
2. Batere Tebea Ho Nkontaabu
Battery tebea ho akontaabu no de afã abien titiriw ka ho:Ɔman a Wɔde Di Dwuma (SOC) .neAkwahosan Tebea (SOH) .. SOC kyerɛ mprempren ahoɔden a aka wɔ battery pack no mu na ɛno ne nea wogyina so bu akontaa sɛnea anyinam ahoɔden kar betumi aka. SOH yɛ parameter a wɔde gyina hɔ ma battery no nkwa nna a aka ne akwahosan tebea afoforo.
Ahoɔden sohwɛ hwɛ sɛ bere ankasa -bere ahoɔden a ɛba ne nea ɛba batere no mu no ntra batere ne nhyehyɛe no tumi a ɛde bɛsoa. Nokwarem no, ɔhyew, SOC, ne SOH, ne nneɛma afoforo nya batere a ɛde charge/discharge tumi so nkɛntɛnso. Bere koro no ara mu no, wɔ nhyehyɛe no gyinabea no, ɛsɛ sɛ wɔkwati asiane ahorow te sɛ ɔhyew a ɛboro so ne circuit meltdown. Enti, ahoɔden a wɔde di dwuma no yɛ wiase nyinaa nhyehyɛe a wɔde di dwuma titiriw a wɔde mprempren, ahoɔden, ɔhyew, SOC, ne SOH di dwuma sɛ nneɛma a wɔde hyɛ mu.
Battery voltage, current, ne temperature a wɔbɛhwɛ so de ahwɛ ahu sɛ ɛntra nea ɛfata. Nnɛyi BMS (Battery Management System) nnyɛ sɛ ɛhwɛ battery pack no nyinaa nko na mmom ɛma tumi a wɔayɛ no yiye wɔ ankorankoro cell tebea horow a ɛyɛ den te sɛ overcharging, over-discharging, ne over-temperature so.
Batere no a wɔbɛma ayɛ nwini bere a ne hyew a ɛyɛ adwuma no kɔ soro dodo na wɔma ɛyɛ hyew bere a ɛba fam sen anohyeto a ɛba fam a ɛwɔ ne hyew a ɛfata a wɔde yɛ adwuma no mu na ama batere no akɔ so ayɛ adwuma yiye na ama ɔhyew a ɛkari pɛ wɔ nkwammoaa ankorankoro mu bere a ɛreyɛ adwuma no. Ɔhyew a wɔhwɛ so ho hia titiriw ma batere a wɔde di dwuma wɔ ahoɔden a ɛkɔ soro-a ɛyɛ hyew ne ɔhyew a ɛkɔ soro-mu.
6. Nkonimdi a Ɛkari pɛ
Batere adwumayɛ a ɛnhyia betumi ama batere no nyinaa adwumayɛ so atew na ahobammɔ ho asiane mpo aba. Wɔde kari pɛ sisi nkwammoaa ankorankoro a ɛwɔ batere no mu no ntam de hwɛ hu sɛ nkwammoaa biara a wɔde charge ne nea wɔde fi mu no bɛyɛ pɛpɛɛpɛ sɛnea wobetumi, na ɛnam so ama batere no nyinaa adwumayɛ atu mpɔn.
Adwuma titiriw a ɛwɔ battery management system (BMS) mu ne sɛ ɛbɛma wɔatumi de battery parameters ne nsɛm adi nkitaho ne onboard anaa offboard mfiri, de data ama charge/discharge control ne kar no sohwɛ. Ɛgyina dwumadie no so no, data nsakraeɛ bɛtumi de nkitahodiɛ ntam nkitahodiɛ ahodoɔ adi dwuma, te sɛ analog nsɛnkyerɛnneɛ, PWM nsɛnkyerɛnneɛ, CAN bɔs, anaa I2C serial nkitahodiɛ.
8. Nnipa-Mfiri Nkitahodi (HMI) .
HMI yɛ ntamgyinafoɔ ntamgyinafoɔ ma nnipa-mfiri nkitahodiɛ. Ɛde mfiri a ɛfata a wɔde hyɛ mu ne nea wɔde fi mu di dwuma na ama nkɔmmɔbɔ ne nkitahodi atumi aba nnipa ne mfiri a wɔde di dwuma no ntam wɔ ɔkwan a etu mpɔn so. Wɔ BMS mu no, HMI no de nsɛm a wɔde kyerɛ ne control buttons ne knobs, a wɔahyehyɛ no sɛnea design ahwehwɛde ahorow te ka ho.